CONTROL CABLE (PVC INSULATED) ARMOURED / UNARMOURED

Category:

1.1 kV multicore PVC insulated copper control cable to IS 1554 (Part 1). 1.5 sq. mm and 2.5 sq. mm, 2 to 61 cores, unarmoured (YY), strip armoured (YFY) or wire armoured (YWY).

CONTROL CABLE (PVC INSULATED)
ARMOURED / UNARMOURED

1.1 kV multicore PVC insulated, PVC sheathed copper control cables for control, signalling and instrumentation circuits in panels, plants and substations. Available unarmoured or armoured, with solid or stranded conductors.

  • Voltage grade: 1.1 kV
  • Standard: IS 1554 (Part 1)
  • Conductor: Annealed copper, Class 2 of IS 8130 (tinned on request)
  • Conductor sizes: 1.5 sq. mm and 2.5 sq. mm
  • Cores: 2 to 61
  • Types: Unarmoured (YY), strip armoured (YFY), wire armoured (YWY)

TECHNICAL DETAILS – 1.1 kV 1.5 sq. mm COPPER CONDUCTOR,
PVC INSULATED, ARMOURED / UNARMOURED CONTROL CABLES

Physical Parameters

1.5 sq. mm PVC control cable – physical parameters (IS 1554 Part 1). Cable codes: YY / YFY / YWY
No. of Cores Min. Inner Sheath Thickness Unarmoured (YY) Flat Strip Armoured (YFY) Round Wire Armoured (YWY)
Min. Outer Sheath Overall Dia – Solid Cond. Overall Dia – Std. Cond. Weight – Solid Cond. Weight – Std. Cond. Armour Strip Dimension Min. Outer Sheath Overall Dia – Solid Cond. Overall Dia – Std. Cond. Weight – Solid Cond. Weight – Std. Cond. Nominal Dia of Armour Wire Min. Outer Sheath Overall Dia – Solid Cond. Overall Dia – Std. Cond. Weight – Solid Cond. Weight – Std. Cond.
Nos mm mm mm mm kg/km kg/km mm mm mm mm kg/km kg/km mm mm mm mm kg/km kg/km
2 0.30 1.80 11 11 160 170 N/A N/A N/A N/A N/A N/A 1.40 1.24 13 13 340 360
3 0.30 1.80 11 12 190 200 N/A N/A N/A N/A N/A N/A 1.40 1.24 13 13 360 380
4 0.30 1.80 12 13 220 230 N/A N/A N/A N/A N/A N/A 1.40 1.24 14 14 400 420
5 0.30 1.80 13 14 260 270 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 15 460 480
6 0.30 1.80 14 15 300 310 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 16 510 530
7 0.30 1.80 14 15 280 300 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 16 530 550
10 0.30 1.80 17 18 380 400 N/A N/A N/A N/A N/A N/A 1.40 1.40 19 19 700 740
12 0.30 1.80 18 18 430 450 4×0.8 1.24 18 19 620 640 1.60 1.40 20 20 810 850
14 0.30 1.80 18 19 490 500 4×0.8 1.40 19 20 680 730 1.60 1.40 21 21 880 940
16 0.30 1.80 19 20 540 560 4×0.8 1.40 20 21 760 780 1.60 1.40 22 22 970 1000
19 0.30 2.00 20 21 630 660 4×0.8 1.40 21 22 830 880 1.60 1.40 23 23 1060 1110
24 0.30 2.00 23 25 780 820 4×0.8 1.40 24 25 1020 1070 1.60 1.40 25 25 1220 1340
27 0.30 2.00 24 25 850 890 4×0.8 1.40 24 26 1110 1150 1.60 1.40 26 26 1360 1430
30 0.30 2.00 25 26 930 970 4×0.8 1.40 25 27 1180 1250 1.60 1.40 27 27 1450 1520
37 0.30 2.00 27 28 1100 1150 4×0.8 1.40 27 28 1380 1450 1.60 1.56 29 29 1690 1740
40 0.30 2.00 27 29 1170 1220 4×0.8 1.40 28 29 1460 1530 1.60 1.56 30 30 1780 1870
44 0.30 2.00 30 31 1290 1350 4×0.8 1.56 30 32 1630 1710 1.60 1.56 32 32 1950 2040
52 0.40 2.20 31 33 1520 1590 4×0.8 1.56 32 33 1850 1940 2.00 1.56 34 34 2390 2510
61 0.40 2.20 33 35 1740 1820 4×0.8 1.56 34 35 2090 2210 2.00 1.56 36 36 2660 2780

Electrical Parameters

1.5 sq. mm PVC control cable – electrical parameters
No. of Cores Max. Conductor DC Resistance at 20°C Approx. Conductor AC Resistance Reactance at 50 Hz (Approx.) Capacitance (Approx.) Current Rating – General Purpose Insulation Current Rating – Heat Resisting Insulation Short Circuit Rating for 1 s
at 70°C at 85°C Ground Duct Air Ground Duct Air General Purpose Heat Resisting
N Ω/km Ω/km Ω/km Ω/km µF/km A A A A A A kA kA
2 12.10 14.52 15.20 0.112 0.20 23 20 20 26 24 24 0.173 0.156
3 12.10 14.52 15.20 0.112 0.20 21 17 17 24 21 21 0.173 0.156
4 12.10 14.52 15.20 0.112 0.20 21 17 17 24 21 21 0.173 0.156
5 12.10 14.52 15.20 0.112 0.20 21 17 17 24 21 21 0.173 0.156
6 12.10 14.52 15.20 0.112 0.20 15 13 13 17 16 16 0.173 0.156
7 12.10 14.52 15.20 0.112 0.20 14 13 13 16 15 15 0.173 0.156
10 12.10 14.52 15.20 0.112 0.20 13 11 11 15 13 13 0.173 0.156
12 12.10 14.52 15.20 0.112 0.20 12 10 10 14 12 12 0.173 0.156
14 12.10 14.52 15.20 0.112 0.20 11 10 10 13 12 12 0.173 0.156
16 12.10 14.52 15.20 0.112 0.20 11 9 9 13 11 11 0.173 0.156
19 12.10 14.52 15.20 0.112 0.20 10 9 9 11 11 11 0.173 0.156
24 12.10 14.52 15.20 0.112 0.20 9 8 8 10 10 10 0.173 0.156
27 12.10 14.52 15.20 0.112 0.20 9 8 8 10 10 10 0.173 0.156
30 12.10 14.52 15.20 0.112 0.20 9 7 7 10 8 8 0.173 0.156
37 12.10 14.52 15.20 0.112 0.20 8 7 7 9 8 8 0.173 0.156
40 12.10 14.52 15.20 0.112 0.20 8 7 7 9 8 8 0.173 0.156
44 12.10 14.52 15.20 0.112 0.20 7 7 7 8 7 7 0.173 0.156
52 12.10 14.52 15.20 0.112 0.20 6 6 6 7 7 7 0.173 0.156
61 12.10 14.52 15.20 0.112 0.20 6 6 6 7 7 7 0.173 0.156

Cross-Sectional View

Cross-section of 1.5 sq. mm multicore PVC insulated armoured copper control cable

  1. Conductor: Solid / stranded annealed bare copper as per Class 2 of IS 8130; option: tinned.
  2. Insulation: PVC Type-A / HR PVC Type-C as per IS 5831; nominal thickness 0.80 mm. Core identification: up to 5 cores by colour coding; above 5 cores by colour coding / number printing as per IS 1554 Part 1.
  3. Inner Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS.
  4. Armouring: Single layer of aluminium round wire / flat strip.
  5. Outer Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS. Colour: black or any other colour as per requirement.

TECHNICAL DETAILS – 1.1 kV 2.5 sq. mm COPPER CONDUCTOR,
PVC INSULATED, ARMOURED / UNARMOURED CONTROL CABLES

Physical Parameters

2.5 sq. mm PVC control cable – physical parameters (IS 1554 Part 1). Cable codes: YY / YFY / YWY
No. of Cores Min. Inner Sheath Thickness Unarmoured (YY) Flat Strip Armoured (YFY) Round Wire Armoured (YWY)
Min. Outer Sheath Overall Dia – Solid Cond. Overall Dia – Std. Cond. Weight – Solid Cond. Weight – Std. Cond. Armour Strip Dimension Min. Outer Sheath Overall Dia – Solid Cond. Overall Dia – Std. Cond. Weight – Solid Cond. Weight – Std. Cond. Nominal Dia of Armour Wire Min. Outer Sheath Overall Dia – Solid Cond. Overall Dia – Std. Cond. Weight – Solid Cond. Weight – Std. Cond.
Nos mm mm mm mm kg/km kg/km mm mm mm mm kg/km kg/km mm mm mm mm kg/km kg/km
2 0.30 1.80 12 13 160 220 N/A N/A N/A N/A N/A N/A 1.40 1.24 14 14 410 440
3 0.30 1.80 13 13 250 260 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 15 430 450
4 0.30 1.80 14 14 300 310 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 16 500 520
5 0.30 1.80 15 15 360 360 N/A N/A N/A N/A N/A N/A 1.40 1.24 17 17 570 590
6 0.30 1.80 16 16 400 420 N/A N/A N/A N/A N/A N/A 1.40 1.24 18 18 630 660
7 0.30 1.80 16 16 390 400 N/A N/A N/A N/A N/A N/A 1.40 1.24 18 18 670 700
10 0.30 1.80 20 20 530 550 4×0.8 1.40 20 21 750 790 1.60 1.40 22 23 960 1010
12 0.30 2.00 21 21 620 650 4×0.8 1.40 21 22 820 870 1.60 1.40 23 24 1040 1100
14 0.30 2.00 21 22 700 730 4×0.8 1.40 22 23 920 970 1.60 1.40 24 24 1150 1190
16 0.30 2.00 22 23 780 810 4×0.8 1.40 23 24 1020 1050 1.60 1.40 25 26 1240 1300
19 0.30 2.00 24 25 890 930 4×0.8 1.40 24 25 1130 1190 1.60 1.40 26 27 1390 1450
24 0.30 2.00 27 29 1110 1150 4×0.8 1.40 28 29 1400 1470 1.60 1.40 30 31 1720 1790
27 0.30 2.00 28 29 1210 1260 4×0.8 1.40 28 30 1510 1580 1.60 1.40 30 32 1840 1920
30 0.30 2.00 29 30 1320 1380 4×0.8 1.56 30 31 1670 1750 1.60 1.40 31 33 1980 2060
37 0.40 2.00 32 33 1630 1700 4×0.8 1.56 32 34 1960 2050 2.00 1.56 34 36 2520 2620
40 0.40 2.00 33 34 1730 1800 4×0.8 1.56 33 35 2080 2160 2.00 1.56 36 37 2620 2740
44 0.40 2.00 35 37 1900 1980 4×0.8 1.56 36 37 2300 2380 2.00 1.56 38 40 2900 3020
52 0.40 2.00 37 38 2190 2280 4×0.8 1.56 37 39 2600 2700 2.00 1.56 40 42 3260 3400
61 0.40 2.00 39 41 2520 2620 4×0.8 1.56 40 41 2950 3050 2.00 1.56 42 44 3640 3810

Electrical Parameters

2.5 sq. mm PVC control cable – electrical parameters
No. of Cores Max. Conductor DC Resistance at 20°C Approx. Conductor AC Resistance Reactance at 50 Hz (Approx.) Capacitance (Approx.) Current Rating – General Purpose Insulation Current Rating – Heat Resisting Insulation Short Circuit Rating for 1 s
at 70°C at 85°C Ground Duct Air Ground Duct Air General Purpose Heat Resisting
N Ω/km Ω/km Ω/km Ω/km µF/km A A A A A A kA kA
2 7.41 8.89 9.34 0.107 0.22 32 27 27 38 32 32 0.288 0.260
3 7.41 8.89 9.34 0.107 0.22 27 24 24 30 28 28 0.288 0.260
4 7.41 8.89 9.34 0.107 0.22 27 24 24 30 28 28 0.288 0.260
5 7.41 8.89 9.34 0.107 0.22 27 24 24 30 28 28 0.288 0.260
6 7.41 8.89 9.34 0.107 0.22 21 18 18 24 21 21 0.288 0.260
7 7.41 8.89 9.34 0.107 0.22 20 17 17 22 20 20 0.288 0.260
10 7.41 8.89 9.34 0.107 0.22 18 15 15 20 16 16 0.288 0.260
12 7.41 8.89 9.34 0.107 0.22 17 14 14 19 16 16 0.288 0.260
14 7.41 8.89 9.34 0.107 0.22 16 13 13 18 15 15 0.288 0.260
16 7.41 8.89 9.34 0.107 0.22 15 13 13 17 15 15 0.288 0.260
19 7.41 8.89 9.34 0.107 0.22 14 12 12 16 14 14 0.288 0.260
24 7.41 8.89 9.34 0.107 0.22 13 11 11 14 13 13 0.288 0.260
27 7.41 8.89 9.34 0.107 0.22 12 10 10 13 12 12 0.288 0.260
30 7.41 8.89 9.34 0.107 0.22 12 10 10 13 12 12 0.288 0.260
37 7.41 8.89 9.34 0.107 0.22 11 9 9 12 10 10 0.288 0.260
40 7.41 8.89 9.34 0.107 0.22 11 9 9 12 10 10 0.288 0.260
44 7.41 8.89 9.34 0.107 0.22 10 9 9 11 10 10 0.288 0.260
52 7.41 8.89 9.34 0.107 0.22 9 8 8 10 10 10 0.288 0.260
61 7.41 8.89 9.34 0.107 0.22 8 8 8 9 9 9 0.288 0.260

Cross-Sectional View

Cross-section of 2.5 sq. mm multicore PVC insulated armoured copper control cable

  1. Conductor: Solid / stranded annealed bare copper as per Class 2 of IS 8130; option: tinned.
  2. Insulation: PVC Type-A / HR PVC Type-C as per IS 5831; nominal thickness 0.90 mm. Core identification: up to 5 cores by colour coding; above 5 cores by colour coding / number printing as per IS 1554 Part 1.
  3. Inner Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS.
  4. Armouring: Single layer of aluminium round wire / flat strip.
  5. Outer Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS. Colour: black or any other colour as per requirement.

* Tabulated approximate weights are a guideline for transportation, loading and unloading only. Values marked “On request” are being confirmed with the manufacturer.
Normal current ratings are given for standard installation conditions. Where site conditions differ, apply the relevant rating factors (available on request).

FREQUENTLY ASKED QUESTIONS

What do YY, YFY and YWY mean for control cables?

YY is PVC insulated, PVC sheathed unarmoured cable. YFY adds a flat strip armour and YWY adds a round wire armour under the outer PVC sheath.

How are cores identified in a multicore control cable?

Cables up to 5 cores use colour coding. Cables above 5 cores use colour coding or number printing on the cores, as per IS 1554 Part 1.

Which control cable size should I choose, 1.5 or 2.5 sq. mm?

1.5 sq. mm suits most control and signalling circuits. 2.5 sq. mm is used where longer runs or higher currents need lower resistance, for example 7.41 Ω/km against 12.10 Ω/km at 20°C.