CONTROL CABLE (XLPE INSULATED)
ARMOURED / UNARMOURED
1.1 kV multicore XLPE insulated, PVC sheathed copper control cables, armoured or unarmoured. XLPE insulation gives a 90°C rating and higher current capacity than PVC control cables of the same size.
- Voltage grade: 1.1 kV
- Standard: IS 7098 (Part 1)
- Conductor: Annealed copper, Class 2 of IS 8130 (tinned on request)
- Insulation: XLPE
- Conductor sizes: 1.5 sq. mm and 2.5 sq. mm
- Cores: 2 to 61
TECHNICAL DETAILS – 1.1 kV 1.5 sq. mm COPPER CONDUCTOR,
XLPE INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Physical Parameters
| No. of Cores | Insulation Thickness (Nom.) | Inner Sheath Thickness | Armour Dimension (Nom.) | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Weight (Copper) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Round Wire | Strip | Round Wire Arm. (Min.) | Flat Strip Arm. (Min.) | Unarmoured (Nom.) | Round Wire Arm. | Flat Strip Arm. | Unarmoured | Round Wire Arm. | Flat Strip Arm. | Unarmoured | |||
| N | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km |
| 2 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 13.0 | – | 11.5 | 350 | – | 175 |
| 3 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 13.5 | – | 12.5 | 385 | – | 195 |
| 4 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 14.5 | – | 13.0 | 440 | – | 225 |
| 5 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 15.5 | – | 13.5 | 460 | – | 235 |
| 6 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 16.5 | – | 14.5 | 520 | – | 270 |
| 7 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 16.5 | – | 14.5 | 520 | – | 275 |
| 10 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 19.5 | – | 18.0 | 680 | – | 370 |
| 12 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 20.0 | – | 18.5 | 735 | – | 415 |
| 19 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.4 | 1.4 | 1.8 | 23.5 | 22.0 | 21.0 | 1030 | 835 | 575 |
| 27 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.4 | 1.4 | 2.0 | 27.0 | 25.5 | 25.0 | 1330 | 1065 | 790 |
| 37 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.4 | 1.4 | 2.0 | 29.5 | 28.5 | 28.0 | 1605 | 1325 | 1005 |
| 44 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.56 | 1.4 | 2.0 | 33.0 | 31.5 | 31.0 | 1900 | 1530 | 1175 |
| 52 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.56 | 1.56 | 2.0 | 34.5 | 33.5 | 32.0 | 2090 | 1745 | 1340 |
| 61 | 0.7 | 0.4 | 2.0 | 4×0.8 | 1.56 | 1.56 | 2.2 | 37.5 | 35.5 | 34.5 | 2560 | 1995 | 1580 |
Electrical Parameters
| No. of Cores | Max. DC Resistance at 20°C | Approx. AC Resistance at 90°C | Capacitance | Approx. Reactance at 50 Hz | Current Rating (Copper) | Short Circuit Rating for 1 s | ||
|---|---|---|---|---|---|---|---|---|
| Direct in Ground at 30°C | In Duct at 30°C | In Air at 40°C | ||||||
| N | Ω/km | Ω/km | µF/km | Ω/km | A | A | A | kA |
| 2 | 12.1 | 15.5 | 0.19 | 0.106 | 33 | 29 | 29 | 0.21 |
| 3 | 12.1 | 15.5 | 0.19 | 0.106 | 25 | 22 | 22 | 0.21 |
| 4 | 12.1 | 15.5 | 0.19 | 0.106 | 25 | 22 | 22 | 0.21 |
| 5 | 12.1 | 15.5 | 0.19 | 0.106 | 24 | 21 | 21 | 0.21 |
| 6 | 12.1 | 15.5 | 0.19 | 0.106 | 22 | 19 | 19 | 0.21 |
| 7 | 12.1 | 15.5 | 0.19 | 0.106 | 21 | 18 | 18 | 0.21 |
| 10 | 12.1 | 15.5 | 0.19 | 0.106 | 18 | 16 | 16 | 0.21 |
| 12 | 12.1 | 15.5 | 0.19 | 0.106 | 17 | 15 | 15 | 0.21 |
| 19 | 12.1 | 15.5 | 0.19 | 0.106 | 15 | 13 | 13 | 0.21 |
| 27 | 12.1 | 15.5 | 0.19 | 0.106 | 13 | 11 | 11 | 0.21 |
| 37 | 12.1 | 15.5 | 0.19 | 0.106 | 11 | 10 | 10 | 0.21 |
| 44 | 12.1 | 15.5 | 0.19 | 0.106 | 11 | 9 | 9 | 0.21 |
| 52 | 12.1 | 15.5 | 0.19 | 0.106 | 10 | 9 | 9 | 0.21 |
| 61 | 12.1 | 15.5 | 0.19 | 0.106 | 9 | 8 | 8 | 0.21 |
Cross-Sectional View
- Conductor: Solid / stranded annealed bare copper as per Class 2 of IS 8130; option: tinned.
- Insulation: XLPE; nominal thickness 0.80 mm. Core identification: up to 5 cores by colour coding; above 5 cores by colour coding / number printing as per IS 1554 Part 1.
- Inner Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS.
- Armouring: Single layer of aluminium round wire / flat strip.
- Outer Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS. Colour: black or any other colour as per requirement.
TECHNICAL DETAILS – 1.1 kV 2.5 sq. mm COPPER CONDUCTOR,
XLPE INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Physical Parameters
| No. of Cores | Insulation Thickness (Nom.) | Inner Sheath Thickness | Armour Dimension (Nom.) | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Weight (Copper) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Round Wire | Strip | Round Wire Arm. (Min.) | Flat Strip Arm. (Min.) | Unarmoured (Nom.) | Round Wire Arm. | Flat Strip Arm. | Unarmoured | Round Wire Arm. | Flat Strip Arm. | Unarmoured | |||
| N | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km |
| 2 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 14.0 | – | 12.5 | 410 | – | 210 |
| 3 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 14.5 | – | 13.0 | 450 | – | 240 |
| 4 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 15.5 | – | 14.0 | 520 | – | 285 |
| 5 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 16.5 | – | 15.0 | 545 | – | 300 |
| 6 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 17.5 | – | 16.0 | 630 | – | 350 |
| 7 | 0.7 | 0.3 | 1.4 | – | 1.24 | – | 1.8 | 17.5 | – | 16.0 | 640 | – | 360 |
| 10 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.4 | 1.24 | 1.8 | 21.5 | 20.0 | 19.5 | 915 | 710 | 485 |
| 12 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.4 | 1.4 | 1.8 | 22.5 | 21.0 | 20.0 | 995 | 790 | 550 |
| 19 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.4 | 1.4 | 2.0 | 25.5 | 24.0 | 23.5 | 1300 | 1060 | 800 |
| 27 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.4 | 1.4 | 2.0 | 29.5 | 28.0 | 27.5 | 1680 | 1400 | 1080 |
| 37 | 0.7 | 0.3 | 1.6 | 4×0.8 | 1.56 | 1.4 | 2.0 | 33.0 | 31.0 | 30.5 | 2105 | 1755 | 1400 |
| 44 | 0.7 | 0.4 | 2.0 | 4×0.8 | 1.56 | 1.56 | 2.2 | 37.5 | 35.5 | 35.0 | 2675 | 2110 | 1690 |
| 52 | 0.7 | 0.4 | 2.0 | 4×0.8 | 1.56 | 1.56 | 2.2 | 39.0 | 37.0 | 36.0 | 2965 | 2370 | 1935 |
| 61 | 0.7 | 0.4 | 2.0 | 4×0.8 | 1.56 | 1.56 | 2.2 | 41.0 | 39.0 | 38.5 | 3315 | 2670 | 2215 |
Electrical Parameters
| No. of Cores | Max. DC Resistance at 20°C | Approx. AC Resistance at 90°C | Capacitance | Approx. Reactance at 50 Hz | Current Rating (Copper) | Short Circuit Rating for 1 s | ||
|---|---|---|---|---|---|---|---|---|
| Direct in Ground at 30°C | In Duct at 30°C | In Air at 40°C | ||||||
| N | Ω/km | Ω/km | µF/km | Ω/km | A | A | A | kA |
| 2 | 7.41 | 9.48 | 0.22 | 0.099 | 39 | 35 | 32 | 0.36 |
| 3 | 7.41 | 9.48 | 0.22 | 0.099 | 34 | 30 | 30 | 0.36 |
| 4 | 7.41 | 9.48 | 0.22 | 0.099 | 34 | 30 | 30 | 0.36 |
| 5 | 7.41 | 9.48 | 0.22 | 0.099 | 31 | 28 | 28 | 0.36 |
| 6 | 7.41 | 9.48 | 0.22 | 0.099 | 29 | 26 | 26 | 0.36 |
| 7 | 7.41 | 9.48 | 0.22 | 0.099 | 27 | 25 | 25 | 0.36 |
| 10 | 7.41 | 9.48 | 0.22 | 0.099 | 24 | 21 | 21 | 0.36 |
| 12 | 7.41 | 9.48 | 0.22 | 0.099 | 22 | 20 | 20 | 0.36 |
| 19 | 7.41 | 9.48 | 0.22 | 0.099 | 19 | 17 | 17 | 0.36 |
| 27 | 7.41 | 9.48 | 0.22 | 0.099 | 16 | 16 | 16 | 0.36 |
| 37 | 7.41 | 9.48 | 0.22 | 0.099 | 15 | 13 | 13 | 0.36 |
| 44 | 7.41 | 9.48 | 0.22 | 0.099 | 14 | 12 | 12 | 0.36 |
| 52 | 7.41 | 9.48 | 0.22 | 0.099 | 13 | 12 | 12 | 0.36 |
| 61 | 7.41 | 9.48 | 0.22 | 0.099 | 12 | 11 | 11 | 0.36 |
Cross-Sectional View
- Conductor: Solid / stranded annealed bare copper as per Class 2 of IS 8130; option: tinned.
- Insulation: XLPE; nominal thickness 0.90 mm. Core identification: up to 5 cores by colour coding; above 5 cores by colour coding / number printing as per IS 1554 Part 1.
- Inner Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS.
- Armouring: Single layer of aluminium round wire / flat strip.
- Outer Sheath: PVC Type ST-1 as per IS 5831; options: PVC Type ST-2 / FR / FRLS. Colour: black or any other colour as per requirement.
* Tabulated approximate weights are a guideline for transportation, loading and unloading only. Values marked “On request” are being confirmed with the manufacturer.
Normal current ratings are given for standard installation conditions. Where site conditions differ, apply the relevant rating factors (available on request).
FREQUENTLY ASKED QUESTIONS
Why choose an XLPE control cable over PVC?
XLPE insulation is rated for 90°C and carries more current than PVC for the same size, for example a 2 core 2.5 sq. mm XLPE control cable is rated 39 A in ground against 32 A for PVC.
Are XLPE control cables available unarmoured?
Yes. They are available unarmoured, flat strip armoured and round wire armoured, from 2 to 61 cores.




